Difference between revisions of "Minutes - Referral WG 2022-02-01"

From Health Level 7 Belgium Wiki
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
==== Attendees ====
 
==== Attendees ====
* TBD 13
+
* Dr Alain Derom
 
* Bart Decuypere
 
* Bart Decuypere
* Frédéric Istace
 
* Frederik De Kegel
 
 
* Frederik Lenaerts  
 
* Frederik Lenaerts  
 
* Hans De Keersmaecker  
 
* Hans De Keersmaecker  
* Hendrik De Moor
 
 
* Jean-Michel Polfiet  
 
* Jean-Michel Polfiet  
* Joost Van Averbeke
+
* José Costa Teixeira - joined late
* José Costa Teixeira  
 
 
* Karlien Erauw  
 
* Karlien Erauw  
 
* Kristof Jaubin  
 
* Kristof Jaubin  
Line 16: Line 12:
 
* Peter Laridon
 
* Peter Laridon
 
* Philippe Cauchie  
 
* Philippe Cauchie  
* Roland Vueghs
 
 
* Sven Bisaro
 
* Sven Bisaro
 
* Thibault Mahieu  
 
* Thibault Mahieu  
 +
* Tom Fiers
 
* Tom Tollenaere  
 
* Tom Tollenaere  
* Veerle Claessens
 
 
* Yulia Shornikova  
 
* Yulia Shornikova  
 +
* Werner De Mulder
  
 
==== Excused/Not present ====  
 
==== Excused/Not present ====  
* Dr Alain Derom
 
 
* Alexis Van Zeveren
 
* Alexis Van Zeveren
 
* Benny Verhamme  
 
* Benny Verhamme  
 +
* Frédéric Istace
 +
* Frederik De Kegel
 
* Filip Migom
 
* Filip Migom
 +
* Hendrik De Moor
 +
* Joost Van Averbeke
 
* Jos Bellen  
 
* Jos Bellen  
 
* Mieke Buckinx
 
* Mieke Buckinx
Line 33: Line 32:
 
* Nico Vannieuwenhuyze  
 
* Nico Vannieuwenhuyze  
 
* Paul Neyens
 
* Paul Neyens
* Peter Laridon
 
 
* Richard Francken  
 
* Richard Francken  
 
* Robert Nicolas
 
* Robert Nicolas
 +
* Roland Vueghs
 
* Theo Schumacher  
 
* Theo Schumacher  
* Tom Fiers
 
 
* Toon Schiemsky  
 
* Toon Schiemsky  
 
* Richard Francken  
 
* Richard Francken  
 
* Stefan Waegemans  
 
* Stefan Waegemans  
* Werner De Mulder
+
* Veerle Claessens
  
 
==== Agenda ====
 
==== Agenda ====
Line 48: Line 46:
 
==== Minutes ====
 
==== Minutes ====
 
* Up-to-date list of issues can be consulted [https://github.com/hl7-be/hl7-be-fhir-laboratory-report/issues here]
 
* Up-to-date list of issues can be consulted [https://github.com/hl7-be/hl7-be-fhir-laboratory-report/issues here]
* Issue #75: not put clinical information in the narrative - is confirmed
+
* Update from last week's resolutions:
* Issue 64 & 65: proposed solution of Annotation Code has been tested and seems ok
+
::* Issue #75: not put clinical information in the narrative - is confirmed
 +
::* Issue 64 & 65: proposed solution of AnnotationCode has been tested and seems ok
  
 
* Issue 87: new issue raised by Thibault
 
* Issue 87: new issue raised by Thibault
 
::* linking requests to multiple specimens
 
::* linking requests to multiple specimens
 
::* FHIR int'l specification: cardinality is 0:1 so max 1 specimen - int'l specification cannot be  
 
::* FHIR int'l specification: cardinality is 0:1 so max 1 specimen - int'l specification cannot be  
::::* add field to put additional specimens
+
::::* add field to put additionalSpecimens
 +
::::* every lab does this daily so we need to check how this is dealt with internationally
 +
::::* do we need to link the results to the sample ?
  
* The group agrees on this resolutions using annotation code
+
* Issue 86: UCUM vs display value
* The following are the agreed values for the valueset to start with: lab-test-accreditation, lab-test-subcontractor , lab-referencerange-comment
+
::* unit is the display value, code contains the UCUM unit
* There are comments regarding the test that are put in the note field
 
::* the note can still be used as a plain text field since annotation code is optional
 
::* plain text with 2 annotation code is possible as 3 notes as it is 1 to many
 
  
* Observation - text: markdown :  you can plain text or any markdown (string <> plain text - html can be put in string)
+
* Issue 81: ObservationInterpretation coding system
::* end user can see weird characters
+
::* limit to HH - H - N - L -LL which is a subset of the indicated codeSystem https://terminology.hl7.org/3.0.0/CodeSystem-v3-ObservationInterpretation.html
::* We try is we can put markdown as string as it is not our objective to use markdown in Belgium : is not possible, so we need to add something in guidance : plain text without markdown is strongly recommended
+
::* this one can be used now
 +
::::* Thibault would like to add A and AA to the list - will be added
 +
::* other values could be added later on
  
 +
* Issue 82: add the use of Quantity:code/unit to guidance
 +
::* the use of Quantity:code is mandatory and will be used by the visualizer, the use of Quantity:unit is optional
 +
::* the Guidance will be modified soon
  
 +
* Issue 83: use of eHealthBox metadata
 +
::* not related to FHIR so a N/A issue for this WG
 +
::* when sending a prtocol some metadata will be sent
 +
::::* HC-FunctionalType= "fhir-lab"
 +
::::* CM-GeneratingSoftware= ""
 +
::::* CM-GeneratingSoftwareVersion= ""
  
 +
* Issue 21: still open because it has impact on the LabOrder
 +
::* will be dealt with once we start with structured requests/orders
  
 +
* '''Action items''':
 +
::* check out issue on multiple specimens and how this is dealt with at int'l level since cardinality is 0:1
  
 
'''Next Meeting: on Tuesday Feb 15 4PM'''
 
'''Next Meeting: on Tuesday Feb 15 4PM'''

Latest revision as of 13:08, 14 February 2022

Attendees

  • Dr Alain Derom
  • Bart Decuypere
  • Frederik Lenaerts
  • Hans De Keersmaecker
  • Jean-Michel Polfiet
  • José Costa Teixeira - joined late
  • Karlien Erauw
  • Kristof Jaubin
  • Lotte Adriaensen
  • Olivier Lothaire
  • Peter Laridon
  • Philippe Cauchie
  • Sven Bisaro
  • Thibault Mahieu
  • Tom Fiers
  • Tom Tollenaere
  • Yulia Shornikova
  • Werner De Mulder

Excused/Not present

  • Alexis Van Zeveren
  • Benny Verhamme
  • Frédéric Istace
  • Frederik De Kegel
  • Filip Migom
  • Hendrik De Moor
  • Joost Van Averbeke
  • Jos Bellen
  • Mieke Buckinx
  • Nick Hermans
  • Nico Vannieuwenhuyze
  • Paul Neyens
  • Richard Francken
  • Robert Nicolas
  • Roland Vueghs
  • Theo Schumacher
  • Toon Schiemsky
  • Richard Francken
  • Stefan Waegemans
  • Veerle Claessens

Agenda

  • Discuss and resolve open issues

Minutes

  • Up-to-date list of issues can be consulted here
  • Update from last week's resolutions:
  • Issue #75: not put clinical information in the narrative - is confirmed
  • Issue 64 & 65: proposed solution of AnnotationCode has been tested and seems ok
  • Issue 87: new issue raised by Thibault
  • linking requests to multiple specimens
  • FHIR int'l specification: cardinality is 0:1 so max 1 specimen - int'l specification cannot be
  • add field to put additionalSpecimens
  • every lab does this daily so we need to check how this is dealt with internationally
  • do we need to link the results to the sample ?
  • Issue 86: UCUM vs display value
  • unit is the display value, code contains the UCUM unit
  • Issue 81: ObservationInterpretation coding system
  • Thibault would like to add A and AA to the list - will be added
  • other values could be added later on
  • Issue 82: add the use of Quantity:code/unit to guidance
  • the use of Quantity:code is mandatory and will be used by the visualizer, the use of Quantity:unit is optional
  • the Guidance will be modified soon
  • Issue 83: use of eHealthBox metadata
  • not related to FHIR so a N/A issue for this WG
  • when sending a prtocol some metadata will be sent
  • HC-FunctionalType= "fhir-lab"
  • CM-GeneratingSoftware= ""
  • CM-GeneratingSoftwareVersion= ""
  • Issue 21: still open because it has impact on the LabOrder
  • will be dealt with once we start with structured requests/orders
  • Action items:
  • check out issue on multiple specimens and how this is dealt with at int'l level since cardinality is 0:1

Next Meeting: on Tuesday Feb 15 4PM

Meetings are happening again biweekly