Difference between revisions of "Minutes - Referral WG 2020-11-09"
From Health Level 7 Belgium Wiki
KarlienErauw (talk | contribs) (Created page with "===== Attendees ===== * Robin Bosman * Jamie Verelst * Benny Verhamme * Dieter De Gruyter * Jos Bellen * Kristof Jaubin * Tom De Backer * Filip Jacobs * Frederik De Kegel * Fr...") |
KarlienErauw (talk | contribs) |
||
(11 intermediate revisions by the same user not shown) | |||
Line 10: | Line 10: | ||
* Frederik De Kegel | * Frederik De Kegel | ||
* Frederic Istace | * Frederic Istace | ||
− | + | * Andries Demont | |
+ | * Dr Alain Derom | ||
===== Excused ===== | ===== Excused ===== | ||
Line 17: | Line 18: | ||
===== Agenda ===== | ===== Agenda ===== | ||
+ | * feedback on draft implementation guide | ||
===== Minutes ===== | ===== Minutes ===== | ||
+ | * Robin gives a demo of [https://github.com/orgs/hl7-be/projects/7 HL7 Belgium on github] | ||
+ | * On [http://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/ build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/] check out the Guidance and Detailed Specifications, Artifacts | ||
+ | * Feedback can be given through the notepad icon on the top right of each textblock which opens a feedback form | ||
+ | * Feedback arrives in an [https://github.com/hl7-be/hl7-be-fhir-laboratory-report/issues/ issue log] | ||
+ | ::* [https://github.com/hl7-be/hl7-be-fhir-laboratory-report/issues/6 clarification needed] on "The laboratory report SHALL also identify itself using a business identifier in the DiagnosticReport.identifier element." : we agree that the use of this shall be in the following way: the combination of system & identifier needs to be globally unique. Typically, the laboratory assigns an identifier that will remain the same during eventual different versions. | ||
+ | ::* [https://github.com/hl7-be/hl7-be-fhir-laboratory-report/issues/8 when to replace the lab report or when to add a new version] : the extra HL7 extensions on replace, extend and addendum are removed for now. As the vital element of a laboratory report, the Observation, also carries a distinct status ([https://www.hl7.org/fhir/valueset-observation-status.html) www.hl7.org/fhir/valueset-observation-status.html)]. It is up to a receiving consumer, when he receives a new version of a report to correctly interpret any updated status on an Observation. When a diagnosticReport is solicited by a party, it should always receive the most up to date version and again, it is up to the consuming party to correctly interpret statuses. | ||
+ | ::* [https://github.com/hl7-be/hl7-be-fhir-laboratory-report/issues/7 is the usage of UCUM codes considered as mandatory by the Belgian profile] : it shall remain possible to express units using a different way. However, as UCUM provides a standardized syntax to express in theory any type of exotic unit, it is highly recommended to always use the UCUM way to express units. | ||
− | + | '''Next Meeting : Monday November 16 at 4PM''' | |
− | Monday November 16 at 4PM |
Latest revision as of 16:34, 1 December 2020
Contents
Attendees
- Robin Bosman
- Jamie Verelst
- Benny Verhamme
- Dieter De Gruyter
- Jos Bellen
- Kristof Jaubin
- Tom De Backer
- Filip Jacobs
- Frederik De Kegel
- Frederic Istace
- Andries Demont
- Dr Alain Derom
Excused
- Karlien Erauw
- José Costa Teixeira
Agenda
- feedback on draft implementation guide
Minutes
- Robin gives a demo of HL7 Belgium on github
- On build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/ check out the Guidance and Detailed Specifications, Artifacts
- Feedback can be given through the notepad icon on the top right of each textblock which opens a feedback form
- Feedback arrives in an issue log
- clarification needed on "The laboratory report SHALL also identify itself using a business identifier in the DiagnosticReport.identifier element." : we agree that the use of this shall be in the following way: the combination of system & identifier needs to be globally unique. Typically, the laboratory assigns an identifier that will remain the same during eventual different versions.
- when to replace the lab report or when to add a new version : the extra HL7 extensions on replace, extend and addendum are removed for now. As the vital element of a laboratory report, the Observation, also carries a distinct status (www.hl7.org/fhir/valueset-observation-status.html). It is up to a receiving consumer, when he receives a new version of a report to correctly interpret any updated status on an Observation. When a diagnosticReport is solicited by a party, it should always receive the most up to date version and again, it is up to the consuming party to correctly interpret statuses.
- is the usage of UCUM codes considered as mandatory by the Belgian profile : it shall remain possible to express units using a different way. However, as UCUM provides a standardized syntax to express in theory any type of exotic unit, it is highly recommended to always use the UCUM way to express units.
Next Meeting : Monday November 16 at 4PM