Difference between revisions of "Minutes - Referral WG 2021-11-30"
From Health Level 7 Belgium Wiki
KarlienErauw (talk | contribs) |
KarlienErauw (talk | contribs) |
||
Line 2: | Line 2: | ||
* Dr Alain Derom | * Dr Alain Derom | ||
* Bart Decuypere | * Bart Decuypere | ||
− | |||
− | |||
* Frederik Lenaerts | * Frederik Lenaerts | ||
* Hans De Keersmaecker | * Hans De Keersmaecker | ||
* Jean-Michel Polfiet | * Jean-Michel Polfiet | ||
+ | * Jonathan Capitano | ||
* Joost Van Averbeke | * Joost Van Averbeke | ||
− | + | * José Schoonbroodt | |
* José Costa Teixeira | * José Costa Teixeira | ||
* Karlien Erauw | * Karlien Erauw | ||
* Kristof Jaubin | * Kristof Jaubin | ||
− | |||
* Nico Vannieuwenhuyze | * Nico Vannieuwenhuyze | ||
+ | * Olivier Lothaire | ||
* Peter Laridon | * Peter Laridon | ||
* Philippe Cauchie | * Philippe Cauchie | ||
− | |||
* Thibault Mahieu | * Thibault Mahieu | ||
+ | * Tom Fiers | ||
* Tom Tollenaere | * Tom Tollenaere | ||
* Stefan Waegemans | * Stefan Waegemans | ||
− | * | + | * Werner De Mulder |
===== Excused/Not present ===== | ===== Excused/Not present ===== | ||
+ | * Alexic Van Zeveren | ||
* Frederik De Kegel | * Frederik De Kegel | ||
+ | * Jos Bellen | ||
* Mieke Buckinx | * Mieke Buckinx | ||
− | |||
* Paul Neyens | * Paul Neyens | ||
− | |||
* Richard Francken | * Richard Francken | ||
* Theo Schumacher | * Theo Schumacher | ||
− | |||
===== Agenda ===== | ===== Agenda ===== |
Latest revision as of 14:56, 17 January 2022
Attendees
- Dr Alain Derom
- Bart Decuypere
- Frederik Lenaerts
- Hans De Keersmaecker
- Jean-Michel Polfiet
- Jonathan Capitano
- Joost Van Averbeke
- José Schoonbroodt
- José Costa Teixeira
- Karlien Erauw
- Kristof Jaubin
- Nico Vannieuwenhuyze
- Olivier Lothaire
- Peter Laridon
- Philippe Cauchie
- Thibault Mahieu
- Tom Fiers
- Tom Tollenaere
- Stefan Waegemans
- Werner De Mulder
Excused/Not present
- Alexic Van Zeveren
- Frederik De Kegel
- Jos Bellen
- Mieke Buckinx
- Paul Neyens
- Richard Francken
- Theo Schumacher
Agenda
- Rework on issues resulted from the pilot phase
Minutes
- Up-to-date list of issues can always be consulted here
- Issue 19: unique identifier
- naming system would be created for unique identifier for the bundle - one for Belgium
- how do labs need to manage amendments of protocols?
- form of unique identifier
- uniqueness of identifier has to be at lab level
- one lab will do it in this way: protocol order number + version number of the protocol, can be prefixed by the RIZIV number of the lab
- Issue 40: ServiceRequest references
- an order creates a ServiceRequest - should ServiceRequests also be stored in the DiagnosticReport.basedOn ?
- it is not needed to duplicate the references, only put it in DiagnosticReport, if mentioned as suborders at Observation level
- Issue 28: notion of "sequence number" on specimen
- important is to be able to note unique ID of specimen, order of sampling is not useful/not relevant
- no action to be taken
- Issue 20: May url references to identifier systems be empty or dummy ?
- there must also be a url that identifies the system and has to be unique within the namespace it belongs to (per lab) but it can be dummy
- it cannot be empty
- see: "If the system is a URL, it SHOULD resolve. Resolution might be to a web page that describes the identifier system and/or supports look-up of identifiers. Alternatively, it could be to a NamingSystem resource instance. Resolvable URLs are generally preferred by implementers over non-resolvable URNs, particularly opaque URNs such as OIDs (urn:oid:) or UUIDs (urn:uuid:). If used, OIDs and UUIDs may be registered in the HL7 OID registry and SHOULD be registered if the content is shared or exchanged across institutional boundaries."
- should : recommended, see https://datatracker.ietf.org/doc/html/rfc2119
- issue was resolved last week, nothing to be done
- Issue 42
- no action to be taken
- the precision that is mentioned in the FHIR message is the precision that is used by the lab
- Issue 29: notion of "specimen collected after x... min"
- LOINC has different codes, these should be used by the labs, if not, then the interval has to specified separately
- no action to be taken
- Issue 34
- was discussed previously
- if RETAM code exist, it must be used, see https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/guidance.html, 3.10.1 Use of Retam codes
- what with LOINC codes that are not in the RETAM table ? we should make a distinction b/w LOINC codes in RETAM table and the ones that are not - to create new issue on this so that we adapt the guidance
- issue 34 can be closed
Next Meeting: on Tuesday Dec 7 4PM to make progress