Difference between revisions of "Minutes - Referral WG 2020-03-08"
From Health Level 7 Belgium Wiki
KarlienErauw (talk | contribs) |
KarlienErauw (talk | contribs) |
||
Line 1: | Line 1: | ||
===== Attendees ===== | ===== Attendees ===== | ||
− | |||
* Robin Bosman | * Robin Bosman | ||
* Benny Verhamme | * Benny Verhamme | ||
− | |||
* Frederik Lenaerts | * Frederik Lenaerts | ||
* Gaston Verelst | * Gaston Verelst | ||
Line 9: | Line 7: | ||
* Jean-Michel Polfiet | * Jean-Michel Polfiet | ||
* Joost Van Averbeke | * Joost Van Averbeke | ||
− | + | * José Costa Teixeira | |
− | * José Costa Teixeira | ||
* Karlien Erauw | * Karlien Erauw | ||
* Kristof Jaubin | * Kristof Jaubin | ||
* Olivier Lothaire | * Olivier Lothaire | ||
− | + | * Peter Laridon (arrived at 4.30PM) | |
− | * Peter Laridon | + | * Thibault Mahieu |
− | + | * Tom Fiers | |
− | * Thibault Mahieu | ||
− | * Tom Fiers | ||
===== Excused/Not present ===== | ===== Excused/Not present ===== | ||
* Dr Alain Derom | * Dr Alain Derom | ||
+ | * Frank Vandewiele | ||
* Hendrik Plaetinck | * Hendrik Plaetinck | ||
+ | * Jos Bellen | ||
+ | * Paul Neyens | ||
+ | * Theo Schumacher | ||
===== Agenda ===== | ===== Agenda ===== | ||
Line 29: | Line 28: | ||
===== Minutes ===== | ===== Minutes ===== | ||
− | * examples for creatinine clearance & microbiology : have been provided by Benny, thanks for that ; Robin has worked on it, unfortunately not yet published due to HL7 technical issue, they will be published as soon as technical possible | + | * feedback of HL7 international on https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/Observation-obsDynamic1.xml.html |
+ | ::* what if we have a code in the element code and we need to express extra information like relative time, do we need to use an extension and is this the only option ? You can also use Components for that, you can qualify the central codes in an observation. HL7 International shall clarify this | ||
+ | ::::* glucose is not a good example for that | ||
+ | ::::* relativeTimeQualifier is now a component in the [http://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/StructureDefinition-be-observation-laboratory.html lab result profile] | ||
+ | |||
+ | ::* LIS systems will produce content (bundles, contained,...): will the receivers be able to handle all this ? | ||
+ | |||
+ | |||
+ | examples for creatinine clearance & microbiology : have been provided by Benny, thanks for that ; Robin has worked on it, unfortunately not yet published due to HL7 technical issue, they will be published as soon as technical possible | ||
* Robin has been working on several examples: | * Robin has been working on several examples: | ||
::* https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/Observation-obsDynamic0.xml.html | ::* https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/Observation-obsDynamic0.xml.html |
Revision as of 15:30, 8 March 2021
Attendees
- Robin Bosman
- Benny Verhamme
- Frederik Lenaerts
- Gaston Verelst
- Hans De Keersmaecker
- Jean-Michel Polfiet
- Joost Van Averbeke
- José Costa Teixeira
- Karlien Erauw
- Kristof Jaubin
- Olivier Lothaire
- Peter Laridon (arrived at 4.30PM)
- Thibault Mahieu
- Tom Fiers
Excused/Not present
- Dr Alain Derom
- Frank Vandewiele
- Hendrik Plaetinck
- Jos Bellen
- Paul Neyens
- Theo Schumacher
Agenda
- updated items since last meeting
- examples
Minutes
- feedback of HL7 international on https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/Observation-obsDynamic1.xml.html
- what if we have a code in the element code and we need to express extra information like relative time, do we need to use an extension and is this the only option ? You can also use Components for that, you can qualify the central codes in an observation. HL7 International shall clarify this
- glucose is not a good example for that
- relativeTimeQualifier is now a component in the lab result profile
- LIS systems will produce content (bundles, contained,...): will the receivers be able to handle all this ?
examples for creatinine clearance & microbiology : have been provided by Benny, thanks for that ; Robin has worked on it, unfortunately not yet published due to HL7 technical issue, they will be published as soon as technical possible
- Robin has been working on several examples:
- https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/Observation-obsDynamic0.xml.html
- https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/Observation-obsDynamic1.xml.html
- https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/Observation-obsDynamic2.xml.html
- https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/Observation-obsKetonen.xml.html
- https://build.fhir.org/ig/hl7-be/hl7-be-fhir-laboratory-report/Observation-obsUrineScreening.xml.html
- Robin shows first example of lab observation using LOINC code
- extension be-ext-relative-time to include a time concept for f.e. glucose test
- stimulation product and dosage that was given, should be provided in some cases
- Example of observation on urine specimen
- Structured antibiogram
- Action points:
- Robin asks for examples to be converted in FHIR f.e. creatinine clearance with 2 specimens (blood + urine)
- Labo results: please provide feedback on antibiogram example
Next Meeting: Monday March 8 at 4PM