Difference between revisions of "Minutes - Referral WG 2021-11-30"
From Health Level 7 Belgium Wiki
KarlienErauw (talk | contribs) |
KarlienErauw (talk | contribs) |
||
Line 47: | Line 47: | ||
::::* it is not needed to duplicate the references, only put it in DiagnosticReport, if mentioned as suborders at Observation level | ::::* it is not needed to duplicate the references, only put it in DiagnosticReport, if mentioned as suborders at Observation level | ||
* Issue 28: notion of "sequence number" on specimen | * Issue 28: notion of "sequence number" on specimen | ||
− | + | ::* important is to be able to note unique ID of specimen, order of sampling is not useful/not relevant | |
− | + | ::* no action to be taken | |
+ | * Issue 20 : May url references to identifier systems be empty or dummy ? | ||
+ | ::* there must also be a url that identifies the system and has to be unique (per lab) but it can be dummy | ||
+ | ::* issue was resolved last week | ||
+ | * Issue | ||
'''Next Meeting:''' on Tuesday Dec 14 at 1PM or on Dec 7 to make progress - TBC ? | '''Next Meeting:''' on Tuesday Dec 14 at 1PM or on Dec 7 to make progress - TBC ? |
Revision as of 15:28, 30 November 2021
Attendees
19-
- Alexis Van Zeveren (arrived late)
- Dr Alain Derom
- Bart Decuypere
- Benny Verhamme
- Frédéric Istace
- Frederik Lenaerts
- Hans De Keersmaecker
- Jean-Michel Polfiet
- Joost Van Averbeke
- Jos Bellen
- José Costa Teixeira
- Karlien Erauw
- Kristof Jaubin
- Nick Hermans
- Nico Vannieuwenhuyze
- Peter Laridon
- Robert Nicolas (Medispring)
- Thibault Mahieu
- Tom Tollenaere
- Stefan Waegemans
- Toon Schiemsky
Excused/Not present
- Frederik De Kegel
- Mieke Buckinx
- Olivier Lothaire
- Paul Neyens
- Richard Francken
- Theo Schumacher
- Tom Fiers
Agenda
- Rework on issues resulted from the pilot phase
Minutes
- Up-to-date list of issues can always be consulted here
- Issue 19 on unique identifier
- naming system would be created for unique identifier for the bundle - one for Belgium
- how do labs need to manage amendments of protocols?
- form of unique identifier
- uniqueness of identifier has to be at lab level
- one lab will do it in this way: protocol order number + version number of the protocol, can be prefixed by the RIZIV number of the lab
- Issue 40: ServiceRequest references
- an order creates a ServiceRequest - should ServiceRequests also be stored in the DiagnosticReport.basedOn ?
- it is not needed to duplicate the references, only put it in DiagnosticReport, if mentioned as suborders at Observation level
- Issue 28: notion of "sequence number" on specimen
- important is to be able to note unique ID of specimen, order of sampling is not useful/not relevant
- no action to be taken
- Issue 20 : May url references to identifier systems be empty or dummy ?
- there must also be a url that identifies the system and has to be unique (per lab) but it can be dummy
- issue was resolved last week
- Issue
Next Meeting: on Tuesday Dec 14 at 1PM or on Dec 7 to make progress - TBC ?